Laser System/

LBS-mini

Spot shape: Square, rectangle, circle
Beam type: Flat top light
Laser power: 30, 60, 100 (W)
Wavelength: 975 (nm)
Spot size: 100 * 200 170 * 340 (μm)
Spot uniformity: Over 95%
Laser head size: 122 * 40 * 220   (mm)
Laser size: 354 * 133 * 298 (mm)

 

Click to download the product manual


LBS mini is a laser system suitable for Mini LED repair, equipped with an ultra high speed closed-loop control thermometer. Combined with unique optical shaping technology, it can control the size of the light spot within a precise range, achieve highly uniform energy distribution, and precisely control the temperature within a very small range, reducing the probability of product damage during the repair process. It helps customers solve the important problem of low yield of Mini LED production and reduce production losses. In addition, the control software used in the entire system – LASCON ® Software, with real-time temperature measurement and adjustment of laser energy function, universal TCP/IP protocol for easy integration by customers; The software script writing process is simple and easy to get started, making the use and operation of the laser system more convenient and efficient; Can save 500000 processes and 255 process control scripts.

  • Product Details
  • Product parameters
  • Software
  • Application

1、Temperature control

Lascon® controller is connected to the laser. It allows for fast, precise, and accurate material surface temperature control.

The figure shows that the laser system changes the laser temperature through high-speed closed-loop control of the pyrometer feedback, achieving the predetermined temperature curve.

2.Uniform and shaped laser spot

Our top hat beam profile has high beam uniformity. Sharp contours prevent damage to surrounding areas.

Plastic shaped light spots and compatible products.

3.Adaptive spot

  We offer a wide range of profile shapes including squares and rectangles with adjustable spot sizes. Spot sizes can be set to 1:1, 2:1, and 1:2.

 
Laser system specifications
Serial Number Parameter Unit Details
1 Laser power W 30, 60, 100
2 Wavelength nm 975
3 Power adjustment range % 0~100
4 Pilot light Yes
5 Fiber core diameter µm 200 or customized
6 Numerical aperture 0.22
7 Fiber length m 3, 5 or customized
8 Connector SMA905 or D80
9 Input voltage V 200~240(50-60Hz)
10 Operating mode Continous wave (CW)
11 Maximum modulation frequency Hz 20000
12 Control mode External control touch screen, RS232 serial port, analog AD
13 Dimensions (L×W×H) mm 354 * 133 * 298
14 Weight Kg 10.5
15 Cooling method air cooling
16 Working temperature 15-30
17 Storage temperature 5-50
18 Cooling requirement 10 cm open space around it
19 Laser safety class DIN EN 60825-1, class 4
Laser head specifications
Serial Number Parameter Unit LH501 BSH200 LH501-B
1 Power limit W up to 500 up to 200 up to 500
2 Spectral range nm 975 975 450
3 Optics 1″, AR coated, 23mm max aperture
4 Fibre connector FSMA905, D80, LLK-A (connection of various fibre laser collimators available)
5 Fibre diameter µm 100 – 600
6 Numerical aperture 0.22
7 Pilot laser Class 2. Wavelength 650nm +/- 10nm, via fibre coupled pyrometer
8 Ambient temperature 5-55 for operation, no condensation
9 Dimensions mm 122 * 40 * 220
10 Weight kg 1.4
11 Protection IP50
12 CE label According to EU directives for electromagnetic immunity
13 Conformity The RoHS Directive 2011/65/EU of 2011-06-08 with supplement from 2015-03-31 is fulfilled
14 Camera USB2.0 1280 x 1024, coaxial with pyrometer and laser
15 0.8kg without the camera
Controller specifications
Serial Number
Parameter
Unit
Details
1
Temperature range
100 – 2200
2
Spectral range
µm
1.65 – 2 / 1.65 – 2.5
3
Accuracy (e=1, t90=1s, T=25℃)
< 1500℃ 0.3% +/- 2K
4
Repeatability
0.1% +/- 1K
5
Resolution
0.1
6
Response time
ms
1
7
Emissivity
0.01 – 1
8
Analog output
V
0-10 (16Bit configurable using software)
9
Power supply
24V DC, max. 2A
10
Data storage
internal, 500.000 processes, 255 process control scripts
11
Optical fibre length
m
3, 5 or customized
12
Ambient temperature
max 40
13
CE label
According to EU directives for electromagnetic immunity
14
Conformity
The RoHS Directive 2011/65/EU of 2011-06-08 with supplement from 2015-03-31 is fulfilled
15
Software
LASCON® software
16
Position
Coaxial

LASCON® is the process monitoring system with probably the largest distribution in the laser industry. More than 1500 users worldwide in industry and research monitor and regulate their laser processes with LASCON®.

The LASCON Process Manager uses the infrared or 2 color pyrometers to measure the temperature on the workpiece 10,000 times per second and compares the measured temperature with a specified setpoint temperature. From the difference, the systems calculated the rated power for the laser system. This laser system is controlled by an analogue signal so that any laser system can be used with analog voltage power input. But it can also control inductors and other heat sources. The processes are monitored, stored and visualized. The process data of each process can additionally be exported automatically to an external server. Easily programmable scripts can be used to set monitors around setpoint temperatures to create an error signal if the measured temperature is not within the temperature monitor. Especially for laser soldering, the solder wire feeder can also be parameterized and started by software from the script.


MiniLED repair

MiniLED repair is a necessary step in the product manufacturing process, which mainly involves repairing MiniLED components that are damaged during the reflow process due to solder defects, misalignment, burning, and other reasons. There are two heating processes during the MiniLED repair process: first, the faulty component must be removed from the PCB through heating. Secondly, clean the solder pads to ensure correct formation of solder joints, and then place the new miniLED in the desired position and solder it onto the PCB. In order to meet the needs of the MiniLED repair process in the appeal, we provide a standard tool – LBS mini laser system.

在线留言